-'s Active and passive beam application design guide PDF

By -

"This booklet presents instruments and information to layout, fee, and function energetic and passive beam structures to accomplish a decided indoor weather. It additionally offers examples of energetic and passive beam calculations and selections"--

summary: "This booklet presents instruments and tips to layout, fee, and function energetic and passive beam platforms to accomplish a decided indoor weather. It additionally offers examples of lively and passive beam calculations and decisions"

Show description

Read Online or Download Active and passive beam application design guide PDF

Similar ventilation & air conditioning books

Get Facility Piping Systems Handbook PDF

Plan, pick out, layout, specify, and try out complete piping platforms Facility Piping structures instruction manual, moment version , provides an entire layout consultant and reference for all piping structures, together with these in laboratories, and health and wellbeing care amenities. This re-creation comprises metric devices all through; up to date codes and criteria; and new fabric on stream point dimension, ingesting water structures, septic platforms, and scorching water circulating platforms.

New PDF release: Combined cooling, heating and power : decision-making,

A certified reference name written essentially for researchers in thermal engineering, mixed Cooling, Heating and tool: Decision-Making, layout and Optimization summarizes present learn on decision-making and optimization in mixed cooling, heating, and gear (CCHP) structures. The authors supply examples of utilizing those decision-making instruments with 5 examples that run during the e-book.

New PDF release: Surveying for Engineers

The 5th version of Surveying for Engineers units out the fundamental concepts wanted for a high-quality grounding within the topic. overlaying conventional tools and the most recent technological advances this renowned and depended on textbook is filled with transparent illustrations, workouts and labored examples, making it either a finished learn relief for college students and a competent reference instrument for practitioners.

Additional info for Active and passive beam application design guide

Sample text

Support location and installation should be done in accordance with manufacturer’s documentation. Upon final positioning of the beam, all support connections should be adequately tightened and secured. 2 CONNECTION TO WATER SYSTEM Beams are typically connected to the main supply and return water pipes with flexible hoses using threaded connections or push-on fittings to provide some freedom of movement for the beams. Oxygen-diffusion-resistant hoses may prevent diffusion into the water system and minimize corrosion.

The dew-point temperature of the space air is determined by continuous sensing of the space air temperature and relative humidity. The calculated dew point must then be compared to the supply water temperature. 49 Active and Passive Beam Application Design Guide In response to the sensor feedback, chilled-water supply temperature setpoint can be reset above the room dew point or the supply water to the zone can be halted. Figure 10-9 presents a control strategy in which the chilled-water supply temperature is varied in accordance with the space dew-point temperature.

Beam systems are designed to operate dry and do not include filters or condensation collection drains and pipes which require cleaning. 1 Draught Firstly, check that the room air temperature is not too low. Secondly, check that the airflow rate is not too high or too low. Too high an airflow rate may create draught near the floor. Conversely, if the airflow rate is too low or too cold, the air jet may fall unintentionally downwards, which may create draught at the neck level. 2 High Room Air Temperature The following steps should be taken if a high room air temperature report is received: 1.